Control unit for the V11 portable traffic light
The control unit is the command centre of each V11 portable traffic light: it switches the lights on, manages the red-yellow-green cycle, synchronises the two traffic lights and checks the lamps and battery. Each traffic light in the set has its own unit, so a set has two. Order it as a spare when a traffic light unit has failed or been damaged on site.
Compatibility
Used with V11-20 portable traffic light sets without countdown and V11-21 sets with countdown; the countdown is activated from the unit menu.
Settings
The front panel has a two-digit display and buttons for power on and off, start, stop and timing settings, switching to flashing yellow and increasing values. Set the all-red time and the green times for the two phases, from 1 to 99 seconds or from 5 to 495 seconds in x5 mode. The menu lets you select the unit phase (1 or 2), how the yellow light operates and the countdown. Resetting returns all times to 10 seconds.
Connections
It has a connector for the signal head and a 12 V power cable. A panel indicator shows when the protective fuse has blown.
Synchronisation
The unit keeps time using an internal clock, so the two traffic lights do not need a cable between them. Synchronise them manually: place the lights next to each other, set the same times on both units and press START on both simultaneously. Synchronisation must be repeated at least once every 6 days; the battery can be changed at any time without losing synchronisation.
Display information
At rest, the display shows the unit phase, F1 or F2. When a problem occurs, it displays a code for a discharged battery, a faulty red, yellow or green light, or a blown fuse.
Technical details
• 12 V power supply;
• operating temperature -20…+70 °C;
• 25 x 20 x 15 cm;
• 1 kg.
Other spare parts
For the V11-20 set, Ø200 mm LED lights are also available in red (V11-D200-R), yellow (V11-D200-Y) and green (V11-D200-G), as well as the complete V11-SUPORT signal head.
Compatible with: V11-20, V11-21
Display: 2 digits (times, phase, error codes)
Adjustable times: all-red, phase 1 green, phase 2 green
Timing range: 1–99 s (5–495 s in x5 mode)
Factory settings: 10 s for each time
Synchronisation: manual, cable-free (internal clock, simultaneous START on both units)
Functions: alternating cycle, flashing yellow, countdown (via menu)
Alarms: faulty lamps, discharged battery, fuse
Connectors: signal head, 12 V power supply
Power supply: 12 V
Operating temperature: -20…+70 °C
Weight: 1 kg
Length: 25 cm
Width: 20 cm
Height: 15 cm